InitialVlans
¶
Used by
-
AsyncevsClient Operationscreate_environment -
evsClient Operationscreate_environment
Source code in docs_src/capo_evs/types/initial_vlans.py
edge_v_tep
instance-attribute
¶
edge_v_tep: InitialVlanInfo
The edge VTEP VLAN subnet. This VLAN subnet manages traffic flowing between the internal network and external networks, including internet access and other site connections.
expansion_vlan1
instance-attribute
¶
expansion_vlan1: InitialVlanInfo
An additional VLAN subnet that can be used to extend VCF capabilities once configured. For example, you can configure an expansion VLAN subnet to use NSX Federation for centralized management and synchronization of multiple NSX deployments across different locations.
expansion_vlan2
instance-attribute
¶
expansion_vlan2: InitialVlanInfo
An additional VLAN subnet that can be used to extend VCF capabilities once configured. For example, you can configure an expansion VLAN subnet to use NSX Federation for centralized management and synchronization of multiple NSX deployments across different locations.
hcx
instance-attribute
¶
hcx: InitialVlanInfo
The HCX VLAN subnet. This VLAN subnet allows the HCX Interconnnect (IX) and HCX Network Extension (NE) to reach their peers and enable HCX Service Mesh creation.
If you plan to use a public HCX VLAN subnet, the following requirements must be met:
-
Must have a /28 netmask and be allocated from the IPAM public pool. Required for HCX internet access configuration.
-
The HCX public VLAN CIDR block must be added to the VPC as a secondary CIDR block.
-
Must have at least two Elastic IP addresses to be allocated from the public IPAM pool for HCX components.
hcx_network_acl_id
instance-attribute
¶
hcx_network_acl_id: NotRequired[NetworkAclId]
A unique ID for a network access control list that the HCX VLAN uses. Required when isHcxPublic is set to true.
is_hcx_public
instance-attribute
¶
is_hcx_public: bool
Determines if the HCX VLAN that Amazon EVS provisions is public or private.
nsx_uplink
instance-attribute
¶
nsx_uplink: InitialVlanInfo
The NSX uplink VLAN subnet. This VLAN subnet allows connectivity to the NSX overlay network.
v_motion
instance-attribute
¶
v_motion: InitialVlanInfo
The vMotion VLAN subnet. This VLAN subnet carries traffic for vSphere vMotion.
v_san
instance-attribute
¶
v_san: InitialVlanInfo
The vSAN VLAN subnet. This VLAN subnet carries the communication between ESX hosts to implement a vSAN shared storage pool.
v_tep
instance-attribute
¶
v_tep: InitialVlanInfo
The VTEP VLAN subnet. This VLAN subnet handles internal network traffic between virtual machines within a VCF instance.
vm_management
instance-attribute
¶
vm_management: InitialVlanInfo
The VM management VLAN subnet. This VLAN subnet carries traffic for vSphere virtual machines.
vmk_management
instance-attribute
¶
vmk_management: InitialVlanInfo
The host VMkernel management VLAN subnet. This VLAN subnet carries traffic for managing ESX hosts and communicating with VMware vCenter Server.