Skip to content

DvbSdtSettings

Source code in docs_src/capo_medialive/types/dvb_sdt_settings.py
class DvbSdtSettings(TypedDict, closed=True):
    output_sdt: NotRequired["capo_medialive.types.dvb_sdt_output_sdt.DvbSdtOutputSdt"]
    """Selects method of inserting SDT information into output stream. The sdtFollow setting copies SDT information from input stream to output stream. The sdtFollowIfPresent setting copies SDT information from input stream to output stream if SDT information is present in the input, otherwise it will fall back on the user-defined values. The sdtManual setting means user will enter the SDT information. The sdtNone setting means output stream will not contain SDT information."""
    rep_interval: NotRequired[
        "capo_medialive.types.__integer_min25_max2000.__integerMin25Max2000"
    ]
    """The number of milliseconds between instances of this table in the output transport stream."""
    service_name: NotRequired[
        "capo_medialive.types.__string_min1_max256.__stringMin1Max256"
    ]
    """The service name placed in the serviceDescriptor in the Service Description Table. Maximum length is 256 characters."""
    service_provider_name: NotRequired[
        "capo_medialive.types.__string_min1_max256.__stringMin1Max256"
    ]
    """The service provider name placed in the serviceDescriptor in the Service Description Table. Maximum length is 256 characters."""

output_sdt instance-attribute

output_sdt: NotRequired[DvbSdtOutputSdt]

Selects method of inserting SDT information into output stream. The sdtFollow setting copies SDT information from input stream to output stream. The sdtFollowIfPresent setting copies SDT information from input stream to output stream if SDT information is present in the input, otherwise it will fall back on the user-defined values. The sdtManual setting means user will enter the SDT information. The sdtNone setting means output stream will not contain SDT information.

rep_interval instance-attribute

rep_interval: NotRequired[__integerMin25Max2000]

The number of milliseconds between instances of this table in the output transport stream.

service_name instance-attribute

service_name: NotRequired[__stringMin1Max256]

The service name placed in the serviceDescriptor in the Service Description Table. Maximum length is 256 characters.

service_provider_name instance-attribute

service_provider_name: NotRequired[__stringMin1Max256]

The service provider name placed in the serviceDescriptor in the Service Description Table. Maximum length is 256 characters.