Creates a new task in the specified workspace. A task defines a reusable containerized compute workload that can be referenced by one or more pipeline compute nodes.
Specify a containerTaskConfiguration for custom container workloads with configurable ECR image, processing type, processing unit, and environment variables.
Parameters:
-
workspace_name(WorkspaceName) –The name of the workspace.
-
task_name(ResourceName) –The name of the task to create. Must be unique within the workspace.
-
description(Optional[Description], default:None) –A description of the task.
-
task_configuration(TaskConfiguration) –The task execution configuration. Specify a containerTaskConfiguration for custom container workloads.
-
tags(Optional[TagMap], default:None) –A list of key-value pairs that contain metadata for the task. For more information, see Tagging your AWS IoT SiteWise resources in the AWS IoT SiteWise User Guide.
-
client_token(Optional[ClientToken], default:None) –A unique, case-sensitive identifier that you provide to ensure the idempotency of the request. If you retry a request that completed successfully using the same client token, the server returns the cached result from the original successful request without performing the operation again.
Raises:
-
AccessDeniedException–Access is denied.
-
ConflictingOperationException–Your request has conflicting operations. This can occur if you're trying to perform more than one operation on the same resource at the same time.
-
InternalFailureException–IoT SiteWise can't process your request right now. Try again later.
-
InvalidRequestException–The request isn't valid. This can occur if your request contains malformed JSON or unsupported characters. Check your request and try again.
-
LimitExceededException–You've reached the quota for a resource. For example, this can occur if you're trying to associate more than the allowed number of child assets or attempting to create more than the allowed number of properties for an asset model.
For more information, see Quotas in the IoT SiteWise User Guide.
-
ResourceNotFoundException–The requested resource can't be found.
-
ThrottlingException–Your request exceeded a rate limit. For example, you might have exceeded the number of IoT SiteWise assets that can be created per second, the allowed number of messages per second, and so on.
For more information, see Quotas in the IoT SiteWise User Guide.
-
UnknownServiceError–The service returned an error code this client does not model.
Source code in docs_src/capo_iotsitewise/_services/async_io_t_site_wise.py
2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 | |